On Fri, 2007-07-27 at 13:34 -0400, DJ Delorie wrote: > > The first I can understand because it would take 2 vias to make it > > work. Its not trivial. > > > > The second I don't understand. It looks trival and yet the line > > stays as a rat instead of routing. Any ideas ? Nothing appears in > > the pcb.log window. > > .pcb file ?
You want me to post it ? > > I've also got a warning message about a cap that is shorted to GND > > and shorted to 5V. That is what I want, right ? Why is it giving > > me a warning ? I had to hand route that because the footprint pin > > identifiers didn't match the symbol. > > Better to fix the footprint to match, else the rats logic will > complain. All it does is compare the netlist to the board, and > complain about anything that differs. OK. That makes sense. > Also, if you move the part to the other side, sometimes it ends up > with the pins swapped, so double check those when you do that. The parts I moved to the other side work fine. They are still autorouting because the footprint worked. I have a couple caps whereby the footprint pins don't match the symbol. _______________________________________________ geda-user mailing list [email protected] http://www.seul.org/cgi-bin/mailman/listinfo/geda-user