Unless something has changed recently, be aware that gnetlist will connect all NC pins together on a net called No-Connect. You may need to manually delete it from the netlist. If you make it "graphical" as Ben suggests, the DRC may not see it(?) and thus can't flag it as an error. (Please chime in if this is wrong.)
Joe T On Nov 13, 2007 4:39 PM, Peter Clifton <[EMAIL PROTECTED]> wrote: > > On Tue, 2007-11-13 at 19:37 -0500, Transistor Toaster wrote: > > > > Thanks Peter, I just put those in. Do you know if there's a DRC to > > flag > > errors on pins that are left totally unconnected (i.e. not even the NC > > symbol)? > > Frank > > Sorry, I don't know.. perhaps some of the DRC proponents will answer > here. > > -- > Peter Clifton > > Electrical Engineering Division, > Engineering Department, > University of Cambridge, > 9, JJ Thomson Avenue, > Cambridge > CB3 0FA > > Tel: +44 (0)7729 980173 - (No signal in the lab!) > > > > _______________________________________________ > geda-user mailing list > geda-user@moria.seul.org > http://www.seul.org/cgi-bin/mailman/listinfo/geda-user >