If your netlist gets large enough you will hit this problem with several of
the scheme back-ends. It has been discussed in the list before. I don't
remember the exact syntax to fix it, but search the archives for stack
overflow 200000 and I'll bet you find it.
Joe T
On Fri, Mar 7, 2008 at 7:13 PM, Kai-Martin Knaak <[EMAIL PROTECTED]>
wrote:
>
> An attempt to do a gnetlist -g drc on my current project yields a stack
> overflow error:
>
> /-------------------------------------
> [EMAIL PROTECTED]:~/geda/DL-strom$ gnetlist -g drc2 strom_0_master.sch -o
> drc_output.txt
> gEDA/gnetlist version 1.5.0.20080127
> gEDA/gnetlist comes with ABSOLUTELY NO WARRANTY; see COPYING for more
> details.
> This is free software, and you are welcome to redistribute it under
> certain
> conditions; please see the COPYING file for more details.
>
> Remember to check that your schematic has no errors using the drc2
> backend.
> You can do it running 'gnetlist -g drc2 your_schematic.sch -o
> drc_output.txt'
> and seeing the contents of the file drc_output.txt.
>
> Loading schematic [/home/kmk/lilalaser/geda/DL-strom/strom_0_master.sch]
> WARNING: Trying to rename something twice:
> +Ub and +Ub
> are both a src and dest name
> This warning is okay if you have multiple levels of hierarchy!
> WARNING: Trying to rename something twice:
> -Ub and -Ub
> are both a src and dest name
> This warning is okay if you have multiple levels of hierarchy!
> Backtrace:
> In /usr/local/geda/share/gEDA/scheme/gnet-drc2.scm:
> 518: 883 (if (null? list) 0 (let ((comparison #)) (if comparison (+ 1 #)
> (+ 0 #))))
> ...
> 525: 884 [+ 0 ...
> 525: 885* [drc2:count-reference-in-list "H1" ("1C101" "1U105" "1U104"
> ...)]
> 518: 886 (if (null? list) 0 ...)
> ...
> 525: 887 [+ 0 ...
> 525: 888* [drc2:count-reference-in-list "H1" ("1U105" "1U104" "1R120"
> ...)]
> 518: 889 (if (null? list) 0 ...)
> ...
> 525: 890 [+ 0 ...
> 525: 891* [drc2:count-reference-in-list "H1" ("1U104" "1R120" "1R117"
> "1C108")]
> 518: 892 (if (null? list) 0 ...)
> ...
> 525: 893 [+ 0 ...
> 525: 894* [drc2:count-reference-in-list "H1" ("1R120" "1R117"
> "1C108")]
> 518: 895 (if (null? list) 0 ...)
> ...
> 525: 896 [+ 0 ...
> 525: 897* [drc2:count-reference-in-list "H1" ("1R117" "1C108")]
> 518: 898 (if (null? list) 0 ...)
> 520: 899 (let ((comparison #)) (if comparison (+ 1 #) (+ 0 #)))
> 520: 900* (if (defined? #) (string-ci=? refdes #) (string=? refdes
> #))
> 520: 901* [defined? ...
> 520: 902* (quote case_insensitive)
>
> /usr/local/geda/share/gEDA/scheme/gnet-drc2.scm:520:58: In expression
> (quote case_insensitive):
> /usr/local/geda/share/gEDA/scheme/gnet-drc2.scm:520:58: Stack overflow
> \--------------------------------
>
> A run of gsch2pcb on the same schematic is successful. So I suspect
> it is a bug in gnetlist rather than in my schematic. Anything I can
> do to help diagnose this illness?
>
> ---<(kaimartin)>---
> --
> Kai-Martin Knaak
> http://lilalaser.de/blog
>
>
>
> _______________________________________________
> geda-user mailing list
> [email protected]
> http://www.seul.org/cgi-bin/mailman/listinfo/geda-user
>