How many +5 and gound net connections are there in your design?

Joe T

On Sat, Jun 14, 2008 at 11:45 PM, Ben Jackson <[EMAIL PROTECTED]> wrote:

> On Sat, Jun 14, 2008 at 12:34:55PM -0400, Ian Chapman wrote:
> > I have a ground plane and I keep connecting 5V to it because the rats
> > show up as an orange ring on both.
>
> I'm not sure I understand your question.  The default color scheme includes
> a light brownish color for rats, and a true orange for "shorted nets" so
> I can't tell which you are referring to.
>
> Here's how I route power/gnd:  Mouse over a known net (ends of a polarized
> cap are often easy) and then hit 'F'.  This 'finds' the matching nets and
> turns them bright green.  This includes the matching rats.  This makes it
> easy to see which ones to route.  If you have the netlist window up, the
> 'f'ind will also highlight the net in that window.
>
> --
> Ben Jackson AD7GD
> <[EMAIL PROTECTED]>
> http://www.ben.com/
>
>
> _______________________________________________
> geda-user mailing list
> [email protected]
> http://www.seul.org/cgi-bin/mailman/listinfo/geda-user
>