On Jul 8, 2008, at 5:49 PM, Gary L. Roach wrote: > On Jul 7, 2008, at 1:49 PM, Gary L. Roach wrote: > >>> Hi >>> >>> I have installed the gEDA suit from Debian and am working >>> through >>> Wilson's gsch2pcb tutorial. Everything works fine except that the >>> slot=1 >>> and slot=2 attributes don't seem to work. The pins on both opamps >>> are >>> numbered 1 - 5. I have re-done the slot attributes several times >>> to no >>> avail. My file setup is identical to the one in the tutorial. All >>> of the >>> information on the status screen, when firing up gschem, seems >>> reasonable. Any suggestions will be appreciated. I am stalled until >>> this >>> is resolved. Please request any additional information that you >>> think >>> might be helpful. >> > In reply to the questions raised by John Doty, Ales Huezda and Dave > N6NZ: > > 1) I am using version 1.4.0.20080127 of gshhem.
OK, that's good. > > 2) As for as the slotted symbol is concerned, I hope this covers it: > Device OpAmp > refdes U101 > symversion 0.1 > netname TL072 netname? This is a mistake! > footprint DIL 8 300 > slot 2 > > The slot 1 device is the same except the slot number. > > 3) I think the slot=2 is applied to the correct component because I > "s" > clicked on the component to highlight, right clicked and selected Edit > to pull up the attribute edit window and then edited slot to = 2. > > 4) In the process of investigating things, I noticed the following in > the log window: > > Read system-gafrc file [/etc/gEDA/system-gafrc] > Read ~/.gEDA/gafrc file [/home/gary/.gEDA/gafrc] > Read local gafrc file [/home/gary/gafrc] > Read system-gschemrc file [/etc/gEDA/system-gschemrc] > Read ~/.gEDA/gschemrc file [/home/gary/.gEDA/gschemrc] > Did not find optional local gschemrc file [/home/gary/gschemrc] > Read init scm file [/usr/share/gEDA/scheme/gschem.scm] > New file [/home/gary/untitled_1.sch] > Closing [/home/gary/untitled_1.sch] > New file [/home/gary/untitled_2.sch] > Read specified gafrc file [/home/gary/gaf/Tutorial/gafrc] > Did not find slotdef=#:#,#,#... attribute > Did not find slotdef=#:#,#,#... attribute > Loading schematic [/home/gary/gaf/Tutorial/one.sch] > Read specified gafrc file [/home/gary/gaf/Tutorial/gafrc] > Did not find slotdef=#:#,#,#... attribute > Did not find slotdef=#:#,#,#... attribute > Zoom too small! Cannot zoom further. > Did not find slotdef=#:#,#,#... attribute It appears you are not using a slotted symbol. Are you perhaps using aop-std-1.sym rather than dual-opamp-1.sym? > > This was generated when starting gschem and editing slot=2 > > I hope this information is helpful. > > GaryR > >>> > > > _______________________________________________ > geda-user mailing list > [email protected] > http://www.seul.org/cgi-bin/mailman/listinfo/geda-user John Doty Noqsi Aerospace, Ltd. http://www.noqsi.com/ [EMAIL PROTECTED] _______________________________________________ geda-user mailing list [email protected] http://www.seul.org/cgi-bin/mailman/listinfo/geda-user