Am Mittwoch, den 19.11.2008, 14:54 +0000 schrieb Peter Clifton: > > Indeed. Unfortunately, test-cases for these kind of things are to build
Indeed my example of lines connected to the 25 pin DSUB connector was bad, because its pins have mil grid (I inserted it yesterday and was assuming mm grid), which will not match to default mm grid. But the problem really exist for lines which are not connected to pins or pads -- as Duncan Drennan verified. Select a mm grid like 0.25mm, draw some connected (diagonal) line segments, and delete the lines. Sometimes garbage points remain. _______________________________________________ geda-user mailing list [email protected] http://www.seul.org/cgi-bin/mailman/listinfo/geda-user