On Fri, 2010-01-15 at 10:36 +0100, Vaclav Peroutka wrote: > Hello all, > > I would like to ask you if there is a new non-cygwin version of > GSchem/GAF for Windows. Somebody compiled one several years ago but > GAF progressed during this time, I feel.
The latest I packaged was the development version 1.5.4, I've not got around to packaging anything later than that. http://www2.eng.cam.ac.uk/~pcjc2/geda-windows.html NB: This also includes PCB and gerbv > Is it possible to set minimum thickness of the copper for polygons ? No > Or the only possibility is to redefine clearance for all pins, pads > and lines ? Yes, select them, then enter an appropriate action command. From the top of my head, I think it is something like: setclearsize(selected,20,mil) setclearsize(selected,0.7,mm) setclearsize(selectedlines,0.7,mm) setclearsize(selectedpins,0.7,mm) setclearsize(selectedpads,0.7,mm) The later forms are useful if you don't want to have to select just lines, for example - it allows you to select everything, then just operate on the lines. > Thank you in advance, hopefully email arrives ok > Vaclav Seems the list is now up and running again. Best wishes, Peter Clifton _______________________________________________ geda-user mailing list [email protected] http://www.seul.org/cgi-bin/mailman/listinfo/geda-user