On Thursday 11 July 2002 04:19 am, [EMAIL PROTECTED] wrote: > Given that the power supply connections for many of the logic symbols in > the gaf library are implicit (not shown, considered evil by some) whats > the way to mix different digital supply voltages in the same design and be > fairly certain of not having the wrong ones connected?
It's not evil, just special case.... the usual way to deal with this is to create a library symbol with explicit pwr gnd, (or even transistor material substrate ), connections, and to create named versions of power and ground like vcca vccd gnda gndd. Separate substrate connectioins might make sense when designing analog silicon on insulator, or memory SOI circuits. John Griessen