On Saturday 01 May 2004 07:39 pm, Bob Paddock wrote: > On Saturday 01 May 2004 10:00 am, Dan McMahill wrote: > > clear the autorouted trace flag on those traces. Its bit 0x8. > > I can't seem to figure out how to do it without editing the > > .pcb file though. There probably is a way though. > > > > in an example.pcb file I have: > > Line[105541 62022 114230 53333 600 600 0x00000080] > > making that be > > Line[105541 62022 114230 53333 600 600 0x00000000] > > makes it not be an autorouted trace any more > > I found you also have to clear the autorouted trace flag in the Via[] > section as well.
Are there any other flags that need to be cleared to turn off auto routed traces? I have a board that has the top section completely finished, I don't want it changed by the autor outer. I'm now working on the botttom section. When I run the auto router for the bottom section, the auto router adds "blobs" to several of the power nets in the top section. It is always a power net, never a signal net, and I don't see what is different between the ones it chooses to blob verses an identical neighbor that it doesn't blob. I've uploaded an example to Source Forges bug tracker page.