Hi James, the error is fixed in CVS. The drc2 output is: Loading schematic [test_drc2.sch] Checking non-numbered parts...
Checking duplicated references... Checking nets with only one connection... Checking type of pins connected to a net... Checking unconnected pins... ERROR: Unconnected pin RP1:7 ERROR: Unconnected pin RP1:2 ERROR: Unconnected pin RP1:8 ERROR: Unconnected pin RP1:1 Checking slots... Checking duplicated slots... Checking unused slots... WARNING: Unused slot 3 of uref RP1 WARNING: Unused slot 4 of uref RP1 Found 2 warnings. Found 4 errors. ERROR: DRC errors found. See output file. Best regards, Carlos El vie, 23-12-2005 a las 11:12 +0100, James Cotton escribió: > I am away from my computer for another week. But i am fairly sure that > i had another symbol i used without that problem. I will get back to > this in a few. > James > > On 12/19/05, Werner Hoch <[EMAIL PROTECTED]> wrote: > > Hi all, > > > > On Sunday 18 December 2005 23:47, James Cotton wrote: > > > Sorry, my bad. It's actually just a resistor with the slotting > > > attributes added plus a dot. Here it is: > > > > [..] > > > pins=2 > > > T 0 0 8 10 0 1 0 0 1 > > > class=DISCRETE > > > T 300 900 8 10 0 0 0 0 1 > > > numslots=8 > > ^^^^^^^^^^^^^^^^^^ > > > > Is the error still there after fixing the numslots attribut. It should > > be 4. > > > > > T 300 1100 8 10 0 0 0 0 1 > > > slotdef=1:1,8 > > > T 300 1300 8 10 0 0 0 0 1 > > > slotdef=2:2,7 > > > T 300 1500 8 10 0 0 0 0 1 > > > slotdef=3:3,6 > > > T 300 1700 8 10 0 0 0 0 1 > > > slotdef=4:4,5 > > > V 100 200 25 3 0 0 0 -1 -1 0 -1 -1 -1 -1 -1 > > > > regards > > Werner