Hi Holger, El dom, 26-02-2006 a las 22:19 +0100, Holger Oehm escribió: > On Sunday 26 February 2006 19:09, Holger Oehm wrote: > > Hi, > > > > some symbols (like 74/7408-1.sym) have hidden power pins. > > If I use them, "gnetlist -g drc2 control.sch -o -" complains > > about pins with pintype 'unknown'. > > How would I specify (in my schematic or in the symbol) that > > the pin 14 is not only connected to the net +5V, but also is of > > type 'pwr'? > > > > Thank you for your help! > > Best, > > Holger. > > I dug into the sources myself and it looks to me that there is > no simple solution for this problem. > I found out that pins which are created by the net= attribute simply > cannot have any other attribute (they are not there as an OBJECT). > One fix could be, to supply a default value for the pintype attribute > for these pins in g_netlist.c, like the following change in [snip]
You are right. AFAIK there is no way to specify the pintype of hidden pins. However, I don't remember any case in which the hidden pins were not power pins, so I think that setting the default pintype value of hidden pins to pwr is ok. If there are no comments about this in a few days, I will review the patch and commit the changes into CVS. Thanks for your work and the attached patch!! Carlos