On Sat, 15 Apr 2006 00:33:39 +0200
Levente <[EMAIL PROTECTED]> wrote:

> Few things I'd like to add:
> 
> * When I hit the F key to look up connection, the lookup is performed on a 
> diferent crosshair position. I think it's still the TAB issue. I don't know 
> this for sure... please find attached a screenshoot, and the pcb file.
> 
> http://web.interware.hu/lekovacs/cuccok/pcb/pcb_F_bug.jpg
> http://web.interware.hu/lekovacs/cuccok/pcb/reflowoven.pcb
> 
> The crosshair was at the place where the black arrow points. (pin 1 of the 
> DB9 connector)

Try the attached patch, which I also just added to CVS.

> * Start the GTK HID pcb, press TAB, and click on "solder mask".  The whole 
> screen should be RED, but only the off-limit area is RED.

I can look at that later.

> * When the F key is pressed on a pin or pad, the Netlist window is raised, 
> and grabs the focus too...

I'm not seeing it grab the focus... do you mean it's grabbing key strokes that 
you intend
for the pcb drawing area?

Bill

Attachment: patch
Description: Binary data