You could use udev to force the devices to get the desired nomenclature. -Tray
On Tue, Dec 14, 2010 at 10:35, Adam Yates <[email protected]> wrote: > Hi all; > I'm having a few problems with a fileserver at work and would like to > bounce some ideas off > anyone that could help. I'm ayates83 on #brlug on irc.freenode.net (does > anyone still inhabit the room?) > Email is fine too. > > Basic setup is this: > > 2 sets raid-6. 22 drives in each set plus a hot spare. > > After I upgraded a kernel, the drives randomly reassign letters under the > raid and cause > the set to break on boot. I can use mdadm --assemble --scan -fv to > forcefully bring the > raid back online but it crashes soon thereafter. > > Any input is appreciated! > > Thanks, > Adam > > -- > Adam Yates > Systems Administrator -- Research Infrastructure > Center for Computation and Technology > 232 Johnston Hall, > Baton Rouge, LA 70803 > W: 225.578.8235 C: 225.663.0218 > <[email protected]> > > > _______________________________________________ > General mailing list > [email protected] > http://brlug.net/mailman/listinfo/general_brlug.net >
_______________________________________________ General mailing list [email protected] http://brlug.net/mailman/listinfo/general_brlug.net