You could use udev to force the devices to get the desired nomenclature.

-Tray


On Tue, Dec 14, 2010 at 10:35, Adam Yates <[email protected]> wrote:

> Hi all;
> I'm having a few problems with a fileserver at work and would like to
> bounce some ideas off
> anyone that could help. I'm ayates83 on #brlug on irc.freenode.net (does
> anyone still inhabit the room?)
> Email is fine too.
>
> Basic setup is this:
>
> 2 sets raid-6. 22 drives in each set plus a hot spare.
>
> After I upgraded a kernel, the drives randomly reassign letters under the
> raid and cause
> the set to break on boot. I can use mdadm --assemble --scan -fv to
> forcefully bring the
> raid back online but it crashes soon thereafter.
>
> Any input is appreciated!
>
> Thanks,
> Adam
>
> --
> Adam Yates
> Systems Administrator -- Research Infrastructure
> Center for Computation and Technology
> 232 Johnston Hall,
> Baton Rouge, LA 70803
> W: 225.578.8235    C: 225.663.0218
> <[email protected]>
>
>
> _______________________________________________
> General mailing list
> [email protected]
> http://brlug.net/mailman/listinfo/general_brlug.net
>
_______________________________________________
General mailing list
[email protected]
http://brlug.net/mailman/listinfo/general_brlug.net

Reply via email to