I should probably clarify what I meant by "supported browsers".
I was thinking in terms of what our Admin UI supports (i.e. what we test
that particular application server with, and the context where we
encountered this bug).
In the context of any particular customer's web app, any browser or
program than can speak HTTP is supported with our server.
Beyond that, it's up to a customer to ensure their particular app works
appropriately with the HTML features and browsers they are using.
Wayne.
On 02/29/2012 01:12 PM, Steve Spigarelli wrote:
We're running ML 4.2-4 where we're having this problem manifest.
On Wed, Feb 29, 2012 at 12:50 PM, Wayne Feick
<[email protected] <mailto:[email protected]>> wrote:
Hi Steve,
Technically, Chrome is not on our list of supported browsers
although some of us do use it regularly so it tends to work. We
encountered this issue recently as well in our own testing and it
will be fixed shortly when 5.0-3 is released. Other browsers seem
to be tolerant of multiple "Location" headers if they have the
same value.
The bug should also be fixed in our next 4.2 maintenance release,
although I don't have any information on when that will happen.
Which release are you running?
Wayne.
On 02/29/2012 11:26 AM, Steve Spigarelli wrote:
Executing this code using the Chrome web browser I get:
"Duplicate headers received from server"
xquery version "1.0-ml";
xdmp:redirect-response("http://example.com"),
xdmp:redirect-response("http://example.com")
Shouldn't this be something that the MarkLogic server can keep
from happening? Or is this useful for something as well?
Thanks
Steve
--
Wayne Feick
Principal Engineer
MarkLogic Corporation
[email protected] <mailto:[email protected]>
Phone:+1 650 655 2378 <tel:%2B1%20650%20655%202378>
www.marklogic.com <http://www.marklogic.com>
This e-mail and any accompanying attachments are confidential. The
information is intended solely for the use of the individual to whom it is
addressed. Any review, disclosure, copying, distribution, or use of this e-mail
communication by others is strictly prohibited. If you are not the intended
recipient, please notify us immediately by returning this message to the sender
and delete all copies. Thank you for your cooperation.
_______________________________________________
General mailing list
[email protected]
<mailto:[email protected]>
http://developer.marklogic.com/mailman/listinfo/general
--
Wayne Feick
Principal Engineer
MarkLogic Corporation
[email protected]
Phone: +1 650 655 2378
www.marklogic.com
This e-mail and any accompanying attachments are confidential. The information
is intended solely for the use of the individual to whom it is addressed. Any
review, disclosure, copying, distribution, or use of this e-mail communication
by others is strictly prohibited. If you are not the intended recipient, please
notify us immediately by returning this message to the sender and delete all
copies. Thank you for your cooperation.
_______________________________________________
General mailing list
[email protected]
http://developer.marklogic.com/mailman/listinfo/general