Thanks folks!
On Thu, Mar 20, 2014 at 5:59 PM, Wayne Feick <[email protected]>wrote: > Hi Guys, > > As of release 7, there is an enable flag in the configuration on the > master side. If you set it to true, replication will cease until you turn > it back on again. > > If you do a large reindex with replication disabled, you will likely end > up doing a bulk resynchronization when you enable replication again (i.e. > your replica database will not be able to serve queries until it > resynchronizes). > > Wayne. > > > > On 03/20/2014 02:32 PM, Gene Thomas wrote: > > Raghu, > > If you are using database replication you should apply you index changes > in the Replica Database before applying them in the Master database. > There is no way that I know to turn off database replication or delay it > apart from deleting the replication entries on the Master. > > Gene > MarkLogic DBA Team Lead - Atos > ------------------------------ > *From:* Raghu > <[email protected]><[email protected]> > *To:* General MarkLogic Developer Discussion > <[email protected]> <[email protected]> > *Sent:* Thursday, March 20, 2014 11:55 AM > *Subject:* [MarkLogic Dev General] Regarding updating index in Master > replica DB > > Hi All, > > My situation is that my customers are using the master DB and I > have to add an index without taking down the DB (which has a foreign > replica). > > If I add an element range index in a Marklogic master DB with > replication turned on with a foreign replica DB. Will the master DB start > reindexing,refragmenting, merging and replication simultaneously? Is there > a way to delay the replication till the reindexing merging stuff etc is > complete without turning the replication off? > > Thanks > Raghu > > _______________________________________________ > General mailing list > [email protected] > http://developer.marklogic.com/mailman/listinfo/general > > > > > _______________________________________________ > General mailing > [email protected]http://developer.marklogic.com/mailman/listinfo/general > > > -- > Wayne Feick > Principal Engineer > MarkLogic [email protected] > Phone: +1 650 655 2378www.marklogic.com > > This e-mail and any accompanying attachments are confidential. The > information is intended solely for the use of the individual to whom it is > addressed. Any review, disclosure, copying, distribution, or use of this > e-mail communication by others is strictly prohibited. If you are not the > intended recipient, please notify us immediately by returning this message to > the sender and delete all copies. Thank you for your cooperation. > > > _______________________________________________ > General mailing list > [email protected] > http://developer.marklogic.com/mailman/listinfo/general > >
_______________________________________________ General mailing list [email protected] http://developer.marklogic.com/mailman/listinfo/general