You'd need to use a vendor class 2 if you wanted to use RMPP as the SA
does. However, there is some rearranging you would need to do if you
compare the relevant MAD formats.

Vendor class 2 just adds the OUI, correct? I guess you could either move the SA specific header by 4-bytes, or use a 32-bit key.

It's not clear to me when to use vendor-specific versus application specific, but I think that we could use application specific as well. The mad layer just wouldn't know to enable RMPP as easily as it does with vendor class 2.

- Sean
_______________________________________________
general mailing list
general@lists.openfabrics.org
http://lists.openfabrics.org/cgi-bin/mailman/listinfo/general

To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general