Hal,

> Where ? In ibsrpdm ?

Yes or in general any one who is reading the SM LID value.

Put another way, how do you know when the SM LID value in
/sys/infiniband/.../sm_lid is the correct value ? Is it
better to check that the value is neither 0x0 nor 0xffff ?

Or do you go by the state of the port (armed or beyond as you mentioned)
and then read the sm_lid value ?

Regards,
Ram