Hi Eitan, On 20:59 Mon 23 Jul , Eitan Zahavi wrote: > Hi Sasha, Hal, > > I think I have an idea: > > Since this is a specific switch that reported ChangeBit or Trap why > can't we just qualify that there was no change in the switch setup?
The ChangeBit seems to be good start point - then OpenSM will query all switch ports PortInfo anyway and if for all ports PortState is <= INIT (and at least for one port it is = INIT), it means that this switch was rebooted/reinitialized. And for single port PortState drop to = INIT should indicate reinitialization. Seems correct? > We could send PortInfo, SwitchInfo, SwitchInfo is queried at each light sweep, PortInfo's if ChangeBit is set. Guess we are ok with it even now. > LFT, MFT, SL2VL, VLArb, PKey queries > and make sure no change from previous state. Or we could simply enforce > last state by sending it over again ... I think we could want to re-read PKey tables in order to preserve existing PKey indices and just to flush (overwrite with new settings) LFT, MFT, SL2VL, VLArb tables. Reasonable? Sasha _______________________________________________ general mailing list [email protected] http://lists.openfabrics.org/cgi-bin/mailman/listinfo/general To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general