On 15:39 Tue 31 Jul     , [EMAIL PROTECTED] wrote:
> 
> 
>    Add common flags -P, -C, and -t to infiniband-diags programs and scripts to
>    allow specifying the HCA port number, HCA device name, and query timeout.
>    These diagnostic programs can now be directed to either different fabrics
>    attached to the system, or forced to use different ports should the fabric
>    fail and comparisons are needed.
> 
>    Two of these had conflicting prior use of the flags.  For the ibcheckerrs
>    script, -T is now used to specify the threshold file.  In the saquery
>    program, -p and -c are now used to specify getting the PathRecord info
>    and getting the SA's class port info.
> 
>    Other than the resolution of the three conflicts, all comands behave 
> exactly
>    the same as they did before the change if these common flags are not used.
> 
> Signed-off-by: David A. McMillen <[EMAIL PROTECTED]>

Great stuff!

Applied. Thanks.

Sasha