On 15:39 Tue 31 Jul , [EMAIL PROTECTED] wrote: > > > Add common flags -P, -C, and -t to infiniband-diags programs and scripts to > allow specifying the HCA port number, HCA device name, and query timeout. > These diagnostic programs can now be directed to either different fabrics > attached to the system, or forced to use different ports should the fabric > fail and comparisons are needed. > > Two of these had conflicting prior use of the flags. For the ibcheckerrs > script, -T is now used to specify the threshold file. In the saquery > program, -p and -c are now used to specify getting the PathRecord info > and getting the SA's class port info. > > Other than the resolution of the three conflicts, all comands behave > exactly > the same as they did before the change if these common flags are not used. > > Signed-off-by: David A. McMillen <[EMAIL PROTECTED]>
Great stuff! Applied. Thanks. Sasha _______________________________________________ general mailing list [email protected] http://lists.openfabrics.org/cgi-bin/mailman/listinfo/general To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general