Hi Amit, On 10:24 Tue 07 Aug , Amit Krig wrote: > Hi Sasha > > In the current switch configurations if you have a single drop (By HOQ), > the line will be flashed for 128 Mili seconds, I think that this penalty > for ~8mili hiccup (as the HOQ can count ~50% less then configured) is > not a good default,
Ok. Let's start from less aggressive default values - HoQ 256msec and VLStallCount 7 (don't need to resubmit the patch for this). Both parameters are configurable anyway and I think it would be nice to make deeper investigation about potentially more optimal default values. Sasha _______________________________________________ general mailing list [email protected] http://lists.openfabrics.org/cgi-bin/mailman/listinfo/general To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general