> From: Tang, Changqing > Sent: Monday, October 01, 2007 11:20 AM > To: [email protected] > Subject: [ofa-general] How to use some ibv_wc fields ? > > > Another question, how is qp number assigned to a QP ? is it a random > number, or > a number from 1 and then increasing with QPs ? one process basis or on > node basis ?
The assignment depends on the specifics of the HCA driver. QP 0 and QP 1 are well known and defined by the spec for management. The remaining 2^24 QPs are up to the hardware and driver. A given QP number is unique per HCA. As QPs are destroyed and created, QP numbers may be reused, however at a given point in time, only a single QP in the HCA will exist with the given number. Todd Rimmer Chief Architect QLogic System Interconnect Group Voice: 610-233-4852 Fax: 610-233-4777 [EMAIL PROTECTED] www.QLogic.com _______________________________________________ general mailing list [email protected] http://lists.openfabrics.org/cgi-bin/mailman/listinfo/general To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general