Steve Wise wrote:
As I mentioned, the nodes with the Chelsio RNICs also have mthca
devices connected to our IB fabric. Are 1.2 and 1.2.5.x meant to
be interoperable?
They should be. Its just that there are a few dozen bug fixes from
1.2 to 1.2.5.4 in the chelsio drivers. Also, if you go up to 1.2.5.4,
you'll need the 5.0 firmware from cheslio's web site. Pull down the
firmware and put it in /lib/firmware. Then it should get upgraded
automagically.
Stevo.
Note there's no interoperability between IB and iWARP... I mean
ofed-1.2 should interoperate with ofed-1.2.5 using the same
devices/transports...
Thanks - that's what I was meaning when I asked. Good to know.
Cheers,
Craig