From: Patrick Marchand Latifi <[EMAIL PROTECTED]>
A work completion entry could be placed on the wrong completion
queue. This can happen when the RC QP is placed in the error
state.
Signed-off-by: Patrick Marchand Latifi <[EMAIL PROTECTED]>
Acked-by: Ralph Campbell <[EMAIL PROTECTED]>
---
drivers/infiniband/hw/ipath/ipath_qp.c | 2 +-
1 files changed, 1 insertions(+), 1 deletions(-)
diff --git a/drivers/infiniband/hw/ipath/ipath_qp.c
b/drivers/infiniband/hw/ipath/ipath_qp.c
index 553d900..087ed31 100644
--- a/drivers/infiniband/hw/ipath/ipath_qp.c
+++ b/drivers/infiniband/hw/ipath/ipath_qp.c
@@ -415,7 +415,7 @@ int ipath_error_qp(struct ipath_qp *qp, enum ib_wc_status
err)
wc.wr_id = qp->r_wr_id;
wc.opcode = IB_WC_RECV;
wc.status = err;
- ipath_cq_enter(to_icq(qp->ibqp.send_cq), &wc, 1);
+ ipath_cq_enter(to_icq(qp->ibqp.recv_cq), &wc, 1);
}
wc.status = IB_WC_WR_FLUSH_ERR;
_______________________________________________
general mailing list
[email protected]
http://lists.openfabrics.org/cgi-bin/mailman/listinfo/general
To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general