> Keep a pointer to the local (src) netdevice in struct rdma_dev_addr. In a
 > High-Availability scheme this information can be used by the rdma-cm to 
 > align RDMA
 > sessions to use the same links as the IP stack does under fail-over and 
 > route change cases.

I don't understand how keeping the netdevice is related to this chunk:

 > --- infiniband.orig/drivers/infiniband/core/cma.c
 > +++ infiniband/drivers/infiniband/core/cma.c
 > @@ -1002,6 +1002,7 @@ static struct rdma_id_private *cma_new_c
 >      union cma_ip_addr *src, *dst;
 >      __be16 port;
 >      u8 ip_ver;
 > +    int ret;
 > 
 >      if (cma_get_net_info(ib_event->private_data, listen_id->ps,
 >                           &ip_ver, &port, &src, &dst))
 > @@ -1026,10 +1027,11 @@ static struct rdma_id_private *cma_new_c
 >      if (rt->num_paths == 2)
 >              rt->path_rec[1] = *ib_event->param.req_rcvd.alternate_path;
 > 
 > -    ib_addr_set_sgid(&rt->addr.dev_addr, &rt->path_rec[0].sgid);
 >      ib_addr_set_dgid(&rt->addr.dev_addr, &rt->path_rec[0].dgid);
 > -    ib_addr_set_pkey(&rt->addr.dev_addr, be16_to_cpu(rt->path_rec[0].pkey));
 > -    rt->addr.dev_addr.dev_type = RDMA_NODE_IB_CA;
 > +    ret = rdma_translate_ip(&id->route.addr.src_addr,
 > +                            &id->route.addr.dev_addr);
 > +    if (ret)
 > +            goto destroy_id;
 > 
 >      id_priv = container_of(id, struct rdma_id_private, id);
 >      id_priv->state = CMA_CONNECT;
_______________________________________________
general mailing list
[email protected]
http://lists.openfabrics.org/cgi-bin/mailman/listinfo/general

To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general

Reply via email to