Phillip Wilson a écrit :
> I updated the HCA "InfiniBand: Mellanox Technologies: Unknown device
> 634a (rev a0)" to the latest firmware and issue remains.  "fw_ver" is
> now 2.6.000.
>  
> Any ideas on why the time out is occuring in the function?
> 
>  
> 

I've seen this problem couples of times.
Something on your system (probably HCA) is in a crappy state and won't answer.

I had the problem (with top spin HCA and old OFED stacks on IA64 system). It 
was due to the driver trying to use msi_x and it failed. 
Try in your modprobe.conf file to force msi=0 msi_x=0 for mlx4_core module, it 
may help :)


Nicolas

_______________________________________________
general mailing list
[email protected]
http://lists.openfabrics.org/cgi-bin/mailman/listinfo/general

To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general