I speak on no particular authority, but I think these are normal
messages, and nothing to be too concerned about.

P

On 10/25/06, Nicolas MASSÉ <[EMAIL PROTECTED]> wrote:
Hello,

I have one RAID 1 array with two ATA hard disks. I noticed a lots of messages
from smartd in my logs.

First, the CRC error count of hdc "goes up" and then "down". What do you think
of this ?

SMART Usage Attribute: 199 UDMA_CRC_Error_Count changed from 195 to 199
SMART Usage Attribute: 199 UDMA_CRC_Error_Count changed from 199 to 198

Then, I have some messages regarding my first disk (hda) :

SMART Prefailure Attribute: 8 Seek_Time_Performance changed from 242 to 245

This message is repeated about ten times a day.

Do you think my disks are going to die in the next days or is smartd
confused ?

Regards,

--
Nicolas MASSÉ
Pour récupérer ma clef GPG:
gpg --keyserver wwwkeys.eu.pgp.net --recv-keys 0x2A18C433
Key fingerprint: 6621 FC23 5DC7 54BA B952 316A 50B1 BC3F 2A18 C433




--
[email protected] mailing list

Reply via email to