Where can I grab a copy of MegaMonitor? The problem is this isn'd a Dell server, this is a Silicon Mechanics server with a MegaRAID card in it.
I'm running 2.6 with the new drivers (megaraid_mm and megaraid_mbox) Regards, Daniel On Thu, 27 Jan 2005 09:24:46 -0800, Matthew Marlowe <[EMAIL PROTECTED]> wrote: > At 08:07 AM 1/27/2005, Daniel Corbe wrote: > >Hello, > > > >I have been trying rather unsucessfully to find monitoring tools for > >the MegaRAID-based RAID cards that will run on Gentoo. Does anyone > >out there have one of these cards? If so, what are you using to > >monitor the status of the array. > > The answer here can get complicated.... > > If you are running a new style megaraid card on a 2.6 kernel, use MegaMonitor. > If you are running on any megaraid on a 2.4 kernel w/ the old megaraid > driver, array status is in /proc/megaraid or /proc/scsi. > If you are running on any megaraid on a newer 2.4 kernel w/ the new > megaraid driver, I'm not sure what you use...probably the array mgr sw. > If you are running an old style megaraid on the the 2.6 kernel using old > driver, I'm also not sure what you use - hopefully stuff shows up in > /proc/megaraid. > > The MegaMonitor and array manager software can be downloaded from the dell > website. > > Note that if you have a new style megaraid card w/ a new style management > card in a recent dell server, the mgmt card will also send out > emails whenever a drive fails and the front server lcd should turn orange > and display an alert message stating which drive has failed. The lights > on the impacted drive should also turn red. > > Regards, > Matt > > -- > [email protected] mailing list > > -- [email protected] mailing list