salut Martin,

On Friday 22 September 2006 07:09, Martin Desruisseaux wrote:
> Raif S. Naffah a écrit :
> > in the class:
> >   org.geotools.referencing.factory.wms.WebCRSFactory
> >
> > in the method:
> >   public CoordinateReferenceSystem
> >   createCoordinateReferenceSystem(String code)
> >   throws FactoryException
> >
> > 1. where does CoordinateReferenceSystem come from?
>
> This is an interface from GeoAPI.
>
> > 2. what is the expected syntax of the code string param; i.e. is
> > "EPSG:4326" a valid value?
>
> No, "EPSG:4326" is for factory defined in
> org.geotools.referencing.factory.epsg package. The values are the ones
> defined in the WMS specification. There is only three valid values at this
> time: "CRS:WGS84", "CRS:NAD83" and "CRS:NAD27".
>
> The org.geotools.referencing.CRS.decode(String) convenience method should
> understand the above codes as well as "EPSG:xxxx" codes.

merci + cheers;
rsn

Attachment: pgphhvnUH3C8p.pgp
Description: PGP signature

-------------------------------------------------------------------------