pespin has posted comments on this change. ( https://gerrit.osmocom.org/c/osmo-gsm-manuals/+/22867 )
Change subject: TRXD: add documentation for TRXDv2 protocol ...................................................................... Patch Set 6: (1 comment) https://gerrit.osmocom.org/c/osmo-gsm-manuals/+/22867/5/common/chapters/trx_if.adoc File common/chapters/trx_if.adoc: https://gerrit.osmocom.org/c/osmo-gsm-manuals/+/22867/5/common/chapters/trx_if.adoc@516 PS5, Line 516: RFU: variable bit-length:: > Not anymore, see commit message I9ac9d387325627d18811fae1d0d7930b69f08129. I'm not following you here. How is it supposed to inform about variable bit length? I see no bit length expressed anywhere, and according to packetdiab above it's one byte. -- To view, visit https://gerrit.osmocom.org/c/osmo-gsm-manuals/+/22867 To unsubscribe, or for help writing mail filters, visit https://gerrit.osmocom.org/settings Gerrit-Project: osmo-gsm-manuals Gerrit-Branch: master Gerrit-Change-Id: I03b2beeb535848b31fd629ba3cd330b43072c08b Gerrit-Change-Number: 22867 Gerrit-PatchSet: 6 Gerrit-Owner: fixeria <vyanits...@sysmocom.de> Gerrit-Reviewer: Jenkins Builder Gerrit-Reviewer: dexter <pma...@sysmocom.de> Gerrit-Reviewer: osmith <osm...@sysmocom.de> Gerrit-CC: laforge <lafo...@osmocom.org> Gerrit-CC: pespin <pes...@sysmocom.de> Gerrit-Comment-Date: Wed, 14 Apr 2021 14:14:06 +0000 Gerrit-HasComments: Yes Gerrit-Has-Labels: No Comment-In-Reply-To: fixeria <vyanits...@sysmocom.de> Comment-In-Reply-To: pespin <pes...@sysmocom.de> Gerrit-MessageType: comment