Attention is currently required from: neels, dexter.

pespin has posted comments on this change. ( 
https://gerrit.osmocom.org/c/osmo-bsc/+/31618 )

Change subject: pcu_sock: handle multiple BTSs with multiple BSC co-located PCUs
......................................................................


Patch Set 7: Code-Review-1

(1 comment)

File include/osmocom/bsc/pcu_if.h:

https://gerrit.osmocom.org/c/osmo-bsc/+/31618/comment/3de10c9e_4c88425f
PS7, Line 11:   struct gsm_bts *bts;            /* BTS that is associated with 
this PCU */
I am really not following here. You are assigning a single BTS to the PCU 
socket? why that limitation? Do you plan to have a PCU socket for each Ericsson 
BTS? That's not how the protocol is envisioned. One PCU socket is used to 
manage several (Ericsson) BTS afaiu, so I don't see why this relation of 1 PCU 
- 1 BTS.



--
To view, visit https://gerrit.osmocom.org/c/osmo-bsc/+/31618
To unsubscribe, or for help writing mail filters, visit 
https://gerrit.osmocom.org/settings

Gerrit-Project: osmo-bsc
Gerrit-Branch: master
Gerrit-Change-Id: I0b42c2c130106f6ffca2dd08d079e1a7bda41f0b
Gerrit-Change-Number: 31618
Gerrit-PatchSet: 7
Gerrit-Owner: dexter <[email protected]>
Gerrit-Reviewer: Jenkins Builder
Gerrit-Reviewer: laforge <[email protected]>
Gerrit-Reviewer: pespin <[email protected]>
Gerrit-CC: neels <[email protected]>
Gerrit-Attention: neels <[email protected]>
Gerrit-Attention: dexter <[email protected]>
Gerrit-Comment-Date: Tue, 07 Mar 2023 10:11:30 +0000
Gerrit-HasComments: Yes
Gerrit-Has-Labels: Yes
Gerrit-MessageType: comment

Reply via email to