Patch Set 1: Code-Review+1 (1 comment)
https://gerrit.osmocom.org/#/c/7316/1/sgsn/SGSN_Tests.ttcn File sgsn/SGSN_Tests.ttcn: Line 330: var hexstring aa_plmn := aa.routingAreaIdentification.mccDigit1 might make sense to put this into a function, to convert ericsson-style 'one record field per nibble' to the hexstring notation that we use in omsocom types? Also, therem might be some overlap to f_RAI() in L3_Common.ttcn? -- To view, visit https://gerrit.osmocom.org/7316 To unsubscribe, visit https://gerrit.osmocom.org/settings Gerrit-MessageType: comment Gerrit-Change-Id: I8901ec0b090e342ebb04a04f9d759fc46c7d9cab Gerrit-PatchSet: 1 Gerrit-Project: osmo-ttcn3-hacks Gerrit-Branch: master Gerrit-Owner: Neels Hofmeyr <[email protected]> Gerrit-Reviewer: Harald Welte <[email protected]> Gerrit-Reviewer: Jenkins Builder Gerrit-HasComments: Yes