laforge has posted comments on this change. ( 
https://gerrit.osmocom.org/c/osmocom-bb/+/18095 )

Change subject: l1ctl: preserve TS configuration for HR channels
......................................................................


Patch Set 1: Code-Review-2

Every L1CTL connection handles one real or virtual MS, and hence only one 
active dedicated channel.  There can never be more than one dedicated chanel 
active concurrently.

You need multiple connections to one L1CTL socket, or multiple L1CTL sockets 
with one connection each in order to model this.

 I think this should be abandoned.


--
To view, visit https://gerrit.osmocom.org/c/osmocom-bb/+/18095
To unsubscribe, or for help writing mail filters, visit 
https://gerrit.osmocom.org/settings

Gerrit-Project: osmocom-bb
Gerrit-Branch: master
Gerrit-Change-Id: I3ac0ae22c40e3cb99c44f1156000c6909f739ad4
Gerrit-Change-Number: 18095
Gerrit-PatchSet: 1
Gerrit-Owner: dexter <[email protected]>
Gerrit-Reviewer: Jenkins Builder
Gerrit-Reviewer: fixeria <[email protected]>
Gerrit-Reviewer: laforge <[email protected]>
Gerrit-CC: pespin <[email protected]>
Gerrit-Comment-Date: Thu, 09 Jul 2020 10:11:57 +0000
Gerrit-HasComments: No
Gerrit-Has-Labels: Yes
Gerrit-MessageType: comment