Hi folks !

Yesterday I got a nice coredump on SIGBUS (on a SUN, which does not forgive
unaligned access like PCs do) when trying to load a 513x513 PPM into a 24 
bit memory visual.

The dump occured in the DrawBox routine and is caused by the assumption that
scanlines start on machine word boundaries.

The bytewise access that is done until alignment is reached does not depend 
on the address, or total offset but rather on the x coordinate in the current
version.

I have temporarily solved my problem by disabling the "highspeed" access 
using 32 bit transfers and just using the fallback at the end of the region.
Could someone fix that right, please ?

Thanks.

-- 
Andreas Beck              |  Email :  <[EMAIL PROTECTED]>

Reply via email to