NoahKusaba opened a new issue, #2964: URL: https://github.com/apache/datafusion-ballista/issues/2964
**Describe the bug** `Float16` arithmetic returns `Float32` batches on Ballista, while the plan's schema (and DataFusion) say `Float16`. This happens with both planners. **To Reproduce** Standalone Ballista on `main` (446fa54c9), default settings: ```sql SELECT column1 + 1::tinyint AS x FROM (VALUES (arrow_cast(1, 'Float16')), (arrow_cast(2, 'Float16'))) t(column1); ``` `DataFrame::schema()` says `x: Float16`, and DataFusion returns `Float16` batches. Ballista returns `Float32` batches. **Expected behavior** `Float16` batches, matching the plan's schema. **Additional context** Found by running DataFusion's sqllogictest files on Ballista (#2945): `float16.slt:24`, `aggregate.slt` 9293 and 9304, `math.slt` 1313, 1319 and 1364. I haven't found where the type changes. -- This is an automated message from the Apache Git Service. To respond to the message, please log on to GitHub and use the URL above to go to the specific comment. To unsubscribe, e-mail: [email protected] For queries about this service, please contact Infrastructure at: [email protected] --------------------------------------------------------------------- To unsubscribe, e-mail: [email protected] For additional commands, e-mail: [email protected]