I'm running gluster on ubuntu Karmic on Amazon EC2, compiled from 3.0.2 source - but io-cache is not working as it complains about missing the symbols "notify" and "dumpops"

Which libraries should I have loaded to provide these?

Config and debug trace below.

Thanks,

Ian

...
[2010-03-04 19:11:47] D [glusterfsd.c:391:_get_specfp] glusterfs: loading volume file from server gb [2010-03-04 19:11:47] D [xlator.c:739:xlator_set_type] xlator: dlsym(notify) on /usr/local/lib/glusterfs/3.0.2/xlator/performance/io-cache.so: undefined symbol: notify -- neglecting [2010-03-04 19:11:47] D [xlator.c:744:xlator_set_type] xlator: dlsym(dumpops) on /usr/local/lib/glusterfs/3.0.2/xlator/performance/io-cache.so: undefined symbol: dumpops -- neglecting
================================================================================
Version      : glusterfs 3.0.2 built on Feb 22 2010 16:41:33
git: v3.0.2
Starting Time: 2010-03-04 19:11:47
Command line : /usr/local/sbin/glusterfs --log-level=DEBUG --volfile-server-port=6996 --volfile-id=web_sites_rw --volfile-server=gb /web/sites
PID          : 32231
System name  : Linux
Nodename     : devu01
Kernel Release : 2.6.31-302-ec2
Hardware Identifier: i686

Given volfile:
+------------------------------------------------------------------------------+
  1: volume gb01_web_sites
  2:     type protocol/client
  3:     option transport-type tcp
  4:     option transport.socket.nodelay on
  5:     option remote-host gb01
  6:     option remote-subvolume export_web_sites
  7: end-volume
  8:
  9: volume gb02_web_sites
 10:     type protocol/client
 11:     option transport-type tcp
 12:     option transport.socket.nodelay on
 13:     option remote-host gb02
 14:     option remote-subvolume export_web_sites
 15: end-volume
 16:
 17: volume mirror_web_sites
 18:     type cluster/replicate
 19:     subvolumes gb01_web_sites gb02_web_sites
 20: end-volume
 21:
 22: #volume quickread_web_sites
 23: #  type performance/quick-read
 24: #  option cache-timeout 60         # default 1 second
 25: #  option max-file-size 256KB        # default 64Kb
 26: #  subvolumes mirror_web_sites
 27: #end-volume
 28:
 29: volume io-cache_web_sites
 30:   type performance/io-cache
 31:   option cache-size 32MB               # default is 32MB
 32:   option cache-timeout 60                # default is 1 second
 33:   subvolumes mirror_web_sites
 34: end-volume
 35:
 36: #volume iothreads_web_sites
 37: #  type performance/io-threads
 38: #  option thread-count 16  # default is 1
 39: #  subvolumes io-cache_web_sites
 40: #end-volume
 41:
 42:
+------------------------------------------------------------------------------+

_______________________________________________
Gluster-users mailing list
[email protected]
http://gluster.org/cgi-bin/mailman/listinfo/gluster-users

Reply via email to