On Wed, 30 Aug 2017 at 20:50, David Gossage <[email protected]>
wrote:

> I've had no issues with mass power outages nodes just came up and were
> healed by time I could start VM's.  I've done rolling updates before as
> well.
>
> However I must have forgotten a step as yesterday I shutdown 1 server in
> my 3-node replicate setup and I have tones of files/shards not healing
> yet.  I've seen it happen in past and I likely just need a relatively short
> downtime this evening where I shutdown every VM on that volume, then kil
> the mounts, and let it heal.
>
> Do I need to just manually kill the pid of volumes when I plan to shutdown
> 1 server instead of letting systemd handle it?
>

It should work in any case.


> Centos 7 servers gluster 3.8.3 (yeah I need to update again)
>
> *David Gossage*
> *Carousel Checks Inc. | System Administrator*
> *Office* 708.613.2284
> _______________________________________________
> Gluster-users mailing list
> [email protected]
> http://lists.gluster.org/mailman/listinfo/gluster-users

-- 
- Atin (atinm)
_______________________________________________
Gluster-users mailing list
[email protected]
http://lists.gluster.org/mailman/listinfo/gluster-users

Reply via email to