I would need following data: * client and brick volume profile - https://glusterdocs.readthedocs.io/en/latest/Administrator%20Guide/Performance%20Testing/ * cmdline of exact test you were running
regards, On Wed, Apr 10, 2019 at 9:02 PM Jeff Forbes <[email protected]> wrote: > I have two CentOS-6 servers running version 3.12.14 of gluster-server. > Each server as one brick and they are configured to replicate between > the two bricks. > > I also have two CentOS-6 servers running version 3.12.2-18 of > glusterfs. > > These servers use a separate VLAN. Each server has two bonded 1 Gbps > NICs to communicate the gluster traffic. File transfer speeds between > these servers using rsync approaches 100 MBps. > > The client servers mount the gluster volume using this fstab entry: > 192.168.40.30:gv0 /store glusterfs defaults, > attribute-timeout=600,entry-timeout=600,negative-timeout=600,fopen-keep-cache,use-readdirp=no,log-level=WARNING > 1 2 > > Reading data from the servers to the clients is similar to the rsync > speed. The problem is that writing from the clients to the mounted > gluster volume is less than 8 MB/s and fluctuates from less than 500 > kB/s to 8 MB/s, as measured by the pv command. Using rsync, the speed > fluctuates between 2 and 5 MBps. > > When the bonded nics on one of the gluster servers is shut down, the > write speed to the remaining online brick is now similar to the read > speed > > I can only assume that there is something wrong in my configuration, > since a greater than 10-fold decrease in write speed when the bricks > are replicating makes for an unusable system. > > > Does anyone have any ideas what the problem may be? > > > Server volume configuration: > > sudo gluster volume info > > Volume Name: gv0 > Type: Replicate > Volume ID: d96bbb99-f264-4655-95ff-f9f05ca9ff55 > Status: Started > Snapshot Count: 0 > Number of Bricks: 1 x 2 = 2 > Transport-type: tcp > Bricks: > Brick1: 192.168.40.20:/export/scsi/brick > Brick2: 192.168.40.30:/export/scsi/brick > Options Reconfigured: > performance.cache-size: 1GB > performance.readdir-ahead: on > features.cache-invalidation: on > features.cache-invalidation-timeout: 600 > performance.stat-prefetch: on > performance.cache-samba-metadata: on > performance.cache-invalidation: on > performance.md-cache-timeout: 600 > network.inode-lru-limit: 250000 > performance.cache-refresh-timeout: 60 > performance.read-ahead: disable > performance.parallel-readdir: on > performance.write-behind-window-size: 4MB > performance.io-thread-count: 64 > performance.client-io-threads: on > performance.quick-read: on > performance.flush-behind: on > performance.write-behind: on > nfs.disable: on > client.event-threads: 3 > server.event-threads: 3 > server.allow-insecure: on > > _______________________________________________ > Gluster-users mailing list > [email protected] > https://lists.gluster.org/mailman/listinfo/gluster-users >
_______________________________________________ Gluster-users mailing list [email protected] https://lists.gluster.org/mailman/listinfo/gluster-users