My mistake ! I used the Code_Aster ordering.
I would give a try to :
map[20] = {0, 3, 2, 1, 4, 7, 6, 5, 8, 9, 13, 11, 16, 17, 19, 18, 10, 15, 14,
12};
I cannot find the HEXA27 numbering for the MED format…
Nicolas
De : [email protected] [mailto:[email protected]]
Envoyé : lundi 28 novembre 2016 20:06
À : TARDIEU Nicolas
Cc : [email protected]
Objet : Re: [Gmsh] Big regression in MED format writing
On 28 Nov 2016, at 17:32, TARDIEU Nicolas
<[email protected]<mailto:[email protected]>> wrote:
Hi Christophe,
It seems to me that the right order should be :
- for MED_HEXA20: map[20] = {0,1,2,3,4,5,6,7,8,11,13,9,10,12,14,15,16,18,19,17
};
- for MED_HEXA27: map[27] =
{0,1,2,3,4,5,6,7,8,11,13,9,10,12,14,15,16,18,19,17,20,21,23,24,22,25,26};
Doesn't seem to work... I found this in the MED doc
[cid:[email protected]][cid:[email protected]]
which (if I understand correctly), would translate into
map[20] = {0, 3, 2, 1, 4, 7, 6, 5, 9, 13, 11, 8, 17, 19, 18, 16, 10, 15, 14,
12};
map[27] = {0, 3, 2, 1, 4, 7, 6, 5, 9, 13, 11, 8, 17, 19, 18, 16, 10, 15, 14,
12, 20, 22, 24, 23, 21, 25, 26};
But this also does not work (I've committed this to SVN) - not sure where I
made the mistake...
Christophe
I can test a nightly build as soon as you integrate this patch.
Regards,
Nicolas
Nicolas Tardieu
Ingénieur Chercheur
Groupe Vibrations des Structures - T63
EDF - R&D Dpt AMA
[email protected]<mailto:[email protected]>
Tél. : 01 78 19 37 49
-----Message d'origine-----
De : [email protected]<mailto:[email protected]>
[mailto:[email protected]]
Envoyé : samedi 26 novembre 2016 18:55
À : TARDIEU Nicolas
Cc : [email protected]<mailto:[email protected]>
Objet : Re: [Gmsh] Big regression in MED format writing
Hello Nicolas,
Indeed! But I'm not sure this has worked in the past...
The correspondance between Gmsh/MED vertices is located in
gmsh/Geo/GModelIO_MED.cpp:
- for MED_HEXA20: map[20] = {0, 3, 2, 1, 4, 7, 6, 5, 11, 8, 16,
10, 19, 9, 18, 17, 15, 12, 14, 13};
this seems to be identical to when it was first implemented...
- for MED_HEXA27: it's actually not implemented ;-)
Could you check the ordering?
Thanks,
Christophe
On 17 Nov 2016, at 10:06, TARDIEU Nicolas
<[email protected]<mailto:[email protected]>> wrote:
Dear Gmsh-team,
I have noticed a big regression in the quadratic hexa writing in MED format.
This can checked by re-reading with Gmsh a MED file produced by Gmsh! The hexa
is totally twisted!
The error appears for the complete and incomplete elements.
Regards,
Nicolas
<cube.geo><cube-hexa20.med><cube-hexa27.med>
Ce message et toutes les pièces jointes (ci-après le 'Message') sont établis à
l'intention exclusive des destinataires et les informations qui y figurent sont
strictement confidentielles. Toute utilisation de ce Message non conforme à sa
destination, toute diffusion ou toute publication totale ou partielle, est
interdite sauf autorisation expresse.
Si vous n'êtes pas le destinataire de ce Message, il vous est interdit de le
copier, de le faire suivre, de le divulguer ou d'en utiliser tout ou partie. Si
vous avez reçu ce Message par erreur, merci de le supprimer de votre système,
ainsi que toutes ses copies, et de n'en garder aucune trace sur quelque support
que ce soit. Nous vous remercions également d'en avertir immédiatement
l'expéditeur par retour du message.
Il est impossible de garantir que les communications par messagerie
électronique arrivent en temps utile, sont sécurisées ou dénuées de toute
erreur ou virus.
____________________________________________________
This message and any attachments (the 'Message') are intended solely for the
addressees. The information contained in this Message is confidential. Any use
of information contained in this Message not in accord with its purpose, any
dissemination or disclosure, either whole or partial, is prohibited except
formal approval.
If you are not the addressee, you may not copy, forward, disclose or use any
part of it. If you have received this message in error, please delete it and
all copies from your system and notify the sender immediately by return message.
E-mail communication cannot be guaranteed to be timely secure, error or
virus-free.
_______________________________________________
gmsh mailing list
[email protected]<mailto:[email protected]>
http://onelab.info/mailman/listinfo/gmsh
--
Prof. Christophe Geuzaine
University of Liege, Electrical Engineering and Computer Science
http://www.montefiore.ulg.ac.be/~geuzaine
Free software: http://gmsh.info | http://getdp.info | http://onelab.info
Ce message et toutes les pièces jointes (ci-après le 'Message') sont établis à
l'intention exclusive des destinataires et les informations qui y figurent sont
strictement confidentielles. Toute utilisation de ce Message non conforme à sa
destination, toute diffusion ou toute publication totale ou partielle, est
interdite sauf autorisation expresse.
Si vous n'êtes pas le destinataire de ce Message, il vous est interdit de le
copier, de le faire suivre, de le divulguer ou d'en utiliser tout ou partie. Si
vous avez reçu ce Message par erreur, merci de le supprimer de votre système,
ainsi que toutes ses copies, et de n'en garder aucune trace sur quelque support
que ce soit. Nous vous remercions également d'en avertir immédiatement
l'expéditeur par retour du message.
Il est impossible de garantir que les communications par messagerie
électronique arrivent en temps utile, sont sécurisées ou dénuées de toute
erreur ou virus.
____________________________________________________
This message and any attachments (the 'Message') are intended solely for the
addressees. The information contained in this Message is confidential. Any use
of information contained in this Message not in accord with its purpose, any
dissemination or disclosure, either whole or partial, is prohibited except
formal approval.
If you are not the addressee, you may not copy, forward, disclose or use any
part of it. If you have received this message in error, please delete it and
all copies from your system and notify the sender immediately by return message.
E-mail communication cannot be guaranteed to be timely secure, error or
virus-free.
--
Prof. Christophe Geuzaine
University of Liege, Electrical Engineering and Computer Science
http://www.montefiore.ulg.ac.be/~geuzaine
Free software: http://gmsh.info | http://getdp.info | http://onelab.info
Ce message et toutes les pièces jointes (ci-après le 'Message') sont établis à
l'intention exclusive des destinataires et les informations qui y figurent sont
strictement confidentielles. Toute utilisation de ce Message non conforme à sa
destination, toute diffusion ou toute publication totale ou partielle, est
interdite sauf autorisation expresse.
Si vous n'êtes pas le destinataire de ce Message, il vous est interdit de le
copier, de le faire suivre, de le divulguer ou d'en utiliser tout ou partie. Si
vous avez reçu ce Message par erreur, merci de le supprimer de votre système,
ainsi que toutes ses copies, et de n'en garder aucune trace sur quelque support
que ce soit. Nous vous remercions également d'en avertir immédiatement
l'expéditeur par retour du message.
Il est impossible de garantir que les communications par messagerie
électronique arrivent en temps utile, sont sécurisées ou dénuées de toute
erreur ou virus.
____________________________________________________
This message and any attachments (the 'Message') are intended solely for the
addressees. The information contained in this Message is confidential. Any use
of information contained in this Message not in accord with its purpose, any
dissemination or disclosure, either whole or partial, is prohibited except
formal approval.
If you are not the addressee, you may not copy, forward, disclose or use any
part of it. If you have received this message in error, please delete it and
all copies from your system and notify the sender immediately by return message.
E-mail communication cannot be guaranteed to be timely secure, error or
virus-free.
_______________________________________________
gmsh mailing list
[email protected]
http://onelab.info/mailman/listinfo/gmsh