Hi

I used the initial minimization run using grompp and mdrun using steepest descent for 400 steps and 0.002 ps as the step size. The constraints are all-atom.

The following is the output from the log file that was generated after the md.
Any suggestions?

Thanks
Was the system already completely munimized, i.e. has it reached convergence? 400 steps seems a bit small to me. I usually had problems with the constraints when the system had some kind of "point of frition" where a bad contact was still existing. Did you check which where the atoms mentioned by the lincs warning or if there were bad angles or contacts in the starting structure?
--
Dipl.-Chem. Steffen Wolf
Department of Biophysics
University of Bochum
ND 04/67
44780 Bochum
Germany


_______________________________________________
gmx-users mailing list    [email protected]
http://www.gromacs.org/mailman/listinfo/gmx-users
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php