karamyog singh wrote:
Does this give any clue. It shows large PE, KE and temp. Could that be a reason? More information required?

Your PE is ridiculously large. You have order 10^5 kJ/mol of PE for every atom, and obviously that is only coming from your LJ function. Check how you generated that and told gromacs what it should be. Be careful of units and multiples of 1000! In the absence of temperature control, that PE will equipartition to the KE degrees of freedom, leading to the other observations of high KE and temperature.

However, I have chenged my system a bit. My conf.gro file has just 2 atoms. one at the origin and the other at the body center. I use genconf to create a mesh of 4x4x4 unit cells at a distance of 0 0 0. I thought this is a better way to simulate a set of crystals.

Sounds like a better way to generate your simulation cells. You shouldn't now have overlapping atoms (check the output .gro file yourself) but you will have a simulation cell that is initially symmetric, until the gen_vel random KE breaks it.

Mark
_______________________________________________
gmx-users mailing list    [email protected]
http://www.gromacs.org/mailman/listinfo/gmx-users
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php