Jianhui Tian wrote:
Hi,
Thank you for the suggestions. The water numbers should be fine. Becuase I can run the same system in AMBER ok. I have done minimization. And the system explodes during the equilibrium process. I compared the energy of different component between AMBER and Gromacs. For all these components, BOND energy always has big difference for the same component between AMBER ang Gromacs. While the ANGLE, DIHEDRAL and LJ etc are consistent with each other. I can't figure out why.
sounds like a periodic boundary problem. do you have molecules that are broken over the PBC? Try to fix that in that case. The mdrun version in CVS can handle it, but not stock 3.3.1

Thanks.
Justin


------------------------------------------------------------------------

_______________________________________________
gmx-users mailing list    gmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php


--
David.
________________________________________________________________________
David van der Spoel, PhD, Assoc. Prof., Molecular Biophysics group,
Dept. of Cell and Molecular Biology, Uppsala University.
Husargatan 3, Box 596,          75124 Uppsala, Sweden
phone:  46 18 471 4205          fax: 46 18 511 755
[EMAIL PROTECTED]       [EMAIL PROTECTED]   http://folding.bmc.uu.se
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++