Maik Goette wrote:
Hi

I just observed very strange results with my system (around 700 atoms in vacuum), when doing normal mode analysis. The eigenvalues were all negative. I then took an old nma-system from Bert de Groot and did the nma with 3.3.1 on it and observed the same strange results. After that I tried 3.2.1 on that system and the results were quite similar to the ones Bert got with 3.1.4. My vacuum-system yields (more or less) correct (not nice) results on the first look.

Is there something new to obey in 3.3.1 what isn't mentioned in the manual (3.11 NMA)?
If not, I would think, there's a bug.
Any suggestions?

Regards

Are you using cut-offs? In that case gromacs uses a different algorithm now, which might cause the problem. Anyway if you have a reproducible problem please report a bugzilla and upload the necessary files.

--
David.
________________________________________________________________________
David van der Spoel, PhD, Assoc. Prof., Molecular Biophysics group,
Dept. of Cell and Molecular Biology, Uppsala University.
Husargatan 3, Box 596,          75124 Uppsala, Sweden
phone:  46 18 471 4205          fax: 46 18 511 755
[EMAIL PROTECTED]       [EMAIL PROTECTED]   http://folding.bmc.uu.se
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
_______________________________________________
gmx-users mailing list    [email protected]
http://www.gromacs.org/mailman/listinfo/gmx-users
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to