Dear gmx-users,

I would like to test the gromacs/CPMD combinaison for  QMMM calculations.
For the system I am interested in, the configuration is "relatively simple", the model contains a single quantum solute molecule surrounded by classical solvent molecules (water, let say). So no broken bonds, and no dummy atoms. But it's complicated because it's a liquid phase.

So i want to build the topology, including for example the "solute.itp" file. What puzzles me, is that i should give some information about a classical force field describing the atoms in my quantum solute... But i cannot set in advance agood classical force field for it:
If I had, i would not bother  about QMMM.

So I have several questions about the gromacs/CPMD:
(1) does gromacs use at the force-field parameters concerning the quantum atoms ?
When and for what ? How critical are those parameters ?
(2) i think about building a quick and dirty approximate classical force field for my solute molecule, in order to create classically a starting point before doing the QMMM. But of course as my force-field is probably bad, the system may explode as soon as i change the model. So do you have some advise how to construct my first system ?
(3)  an other question which is more CPMD related : i am now testing
the  influence of size of the quantum bounding box
and the poisson solver on the electronic structure of my solute.
As i understood, this SYMMETRY 0 is in order to avoid
seeing the electrostatic periodic  images which
are instrinsically present in plane-wave calculation.
In vacuum it's exactly what i want. But my QMMM system is a liquid, i want to have periodic
boundary conditions for my MM box (the gromacs'one, not the CPMD one).
What does the QM system feel if i take the ususal pbc of gromacs input ? Does it see its
periodic  images (I mean with the periodicity of  the MM box ) ?
Do i have to take care that the QM system does not cross the boundary of the MM box ? (4) in the examples from the Gogonea's group ( http://comppsi.csuohio.edu/groups/qmmm.html, which i had difficulties to run, by the way), the gromacs cutoff for the electrostatic interaction is set to 0.
Is that compulsory ?

Thanks for any suggestions and for your understanding about confused questions..