On May 3, 2007, at 12:37 PM, Jones de Andrade wrote:

Hi Berk! Thanks for your so fast answer!

I'll try to look for a different tau_p. I would really feel 4 ps a too high value, even for water systems, but will look around before decision. Anyway, I'm still concerned about the compressibility value.

Long time ago in this list I came to this question, and this is how this ended:

> Hi,
>
> Just use the water value for any liquid system (5e-5 or so).
>

> As the manual explains, it only affects the coupling time, not the
> equilibrium pressure.
>

This is valid for long times, and (as always for pressure) assumes the external coupling to be clearly slower than the internal dynamics. I have no idea how Amber or DLPOLY sets their tau_t with Nose or Parinello-Rahman, but as specified in the Gromacs manual we use the period of average fluctuations at equilibrium. With tau=0.1 the system will very likely never reach that equilibrium.

Cheers,

Erik