So, using twin-range cut-off does not violate the energy conservation for RC 
method, but it violates for PME method. Is this the case ?


-----Original Message-----
From: David van der Spoel <[EMAIL PROTECTED]>
To: Discussion list for GROMACS users <[email protected]>
Date: Sat, 01 Sep 2007 14:48:03 +0200
Subject: Re: [gmx-users] r_list and r_coulomb values while using PME

OZGE ENGIN wrote:
> 'The force is not the derivative of the potential', is it due to the types of 
> calculations performed in PME, using of FFT for reciprocal sum? Because it 
> does not matter while using reaction-field method. 
> Sorry, this phenomenon is  a little complicated to me :) 


this is only when you combine twin range (rcoulomb > rlist) and PME. 
then the forces for a certain distance range are not computed at each 
time step while the others are. you may want to (re)read the PME papers 
and/or the gromacs manual about twin range.
> 
> Thanks for your attention!
> 
> Oz.
> 
> -----Original Message-----
> From: David van der Spoel <[EMAIL PROTECTED]>
> To: Discussion list for GROMACS users <[email protected]>
> Date: Sat, 01 Sep 2007 13:37:05 +0200
> Subject: Re: [gmx-users] r_list and r_coulomb values while using PME
> 
> OZGE ENGIN wrote:
>> Hi all,
>>
>> I can not understand why it is required to take same values for  both r_list 
>> and r_coulomb parameters when using PME for calculation of electrostatic 
>> interactions?
>>
>> I read archieve, and gromacs manual. In archieve, similar question had been 
>> posted, but not replied yet.
>>
>> Thanks in advance
> 
> if rlist < rcoulomb you  will have a twin range interaction, meaning the 
> atom pair interactions for distance between these two will be computed 
> every nstlist steps only, while the interaction beyond rcoulomb will be 
> computed at each time step. this will lead to bad energy conservation, 
> since the force is not the derivative of the potential.
>> Oz.
>>
>> _______________________________________________
>> gmx-users mailing list    [email protected]
>> http://www.gromacs.org/mailman/listinfo/gmx-users
>> Please search the archive at http://www.gromacs.org/search before posting!
>> Please don't post (un)subscribe requests to the list. Use the 
>> www interface or send it to [EMAIL PROTECTED]
>> Can't post? Read http://www.gromacs.org/mailing_lists/users.php
> 
> 


-- 
David van der Spoel, Ph.D.
Molec. Biophys. group, Dept. of Cell & Molec. Biol., Uppsala University.
Box 596, 75124 Uppsala, Sweden. Phone:  +46184714205. Fax: +4618511755.
[EMAIL PROTECTED]       [EMAIL PROTECTED]   http://folding.bmc.uu.se
_______________________________________________
gmx-users mailing list    [email protected]
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php



_______________________________________________
gmx-users mailing list    [email protected]
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the
www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to