Quoting nahren manuel <[EMAIL PROTECTED]>:

> Dear Gromacs Users,
>  
> 1. I calculated the partial charges of my ligand using QM. Since GROMACS
> ignores the non-polar hydrogen, is it a good approximation to include the
> charges as it is from QM method to my ligand heavy atoms ?.

Gromacs does no such thing!  What you're referring to is the *Gromos* force
field, which is an entirely separate idea.

There are all-atom force fields for use with Gromacs - OPLS, Amber, and even
CHARMM, if you're adventurous :-)  What you need to be concerned with is
whether or not these QM charges and methodology are compatible with your force
field of choice.

>  
> 2.  should i adjust that partial charges , If so how to do the same?

See above.

-Justin

>  