sapna sarupria wrote:
Hello,

Thanks David for your response. Actually I have used the same tables for simulations of the polymer in water and have had no problem with them. Those simulations run for 4 ns without a problem. So the tables are correct and I am sure of that. I am not using the CVS version and so I give the energy and second derivative in the table. I have used user-defined tables in the past and so the setup is correct in terms of changing the mdp file and the top file. The problem seems to be more system specific (meaning vacuum) than user error specific. Can you suggest any other thing that may be the problem.

Have you checked energy components, temperature etc.?



Thanks a lot for your help.

Regards
Sapna


On Wed, Jul 16, 2008 at 9:23 AM, David van der Spoel <[EMAIL PROTECTED] <mailto:[EMAIL PROTECTED]>> wrote:

    sapna sarupria wrote:



        ---------- Forwarded message ----------
        From: *sapna sarupria* <[EMAIL PROTECTED]
        <mailto:[EMAIL PROTECTED]>
        <mailto:[EMAIL PROTECTED] <mailto:[EMAIL PROTECTED]>>>
        Date: Tue, Jul 15, 2008 at 9:16 AM
        Subject: Using user-tables for simulations in vacuum
        To: Discussion list for GROMACS users <[email protected]
        <mailto:[email protected]> <mailto:[email protected]
        <mailto:[email protected]>>>


        Hello users,

        I am trying to do a simulation of a polymer chain (which is
        simply a bead of unified methane molecules) in vacuum using
        user-defined tables. The interactions are
        Weeks-Chandler-Andersen instead of Lennard-Jones. However,  when
        I run the simulations, mdrun gives me a segmentation fault. When
        I run simulations for the exact same configurations without the
        tables (and therefore using VdW) the simulations run fine. In
        addition, the starting configurations were obtained after 3ns
        simulations of the polymer in water.

        So I was wondering if there is any issue with using user-defined
        tables with simulations in vacuum. If not do you have any idea
        what could be going wrong.
        Some details of the mdp file:
        1. pbc is turned off.
        2. there is no pressure coupling.
        3. center of mass removal is set to angular.
        4. temperature is 298 K and berendsen thermostat is used.
        5. energy groups and table are defined (correctly).
        6. the cut-offs are set to 1.0nm (box size is larger than 4 nm).
        7. no constraints are being used.


    Most obvious error source is the table itself. Do you use the CVS
    version? In that case you should provide energy and force, otherwise
    energy and second derivative. Distance units are in nm. Compare to
    existing tables in share/gromacs/top


        Thank you

        Regards
        Sapna



-- Sapna Sarupria
        Ph.D. Student - Chemical Engineering
        Rensselaer Polytechnic Institute
        Troy, New York 12180
        U.S.A.
        Ph#: (518)276-3031
        Life isn't about finding yourself. Life is about creating yourself.
        George Bernard Shaw.
        Dare to Dream


        ------------------------------------------------------------------------

        _______________________________________________
        gmx-users mailing list    [email protected]
        <mailto:[email protected]>
        http://www.gromacs.org/mailman/listinfo/gmx-users
        Please search the archive at http://www.gromacs.org/search
        before posting!
        Please don't post (un)subscribe requests to the list. Use the
        www interface or send it to [EMAIL PROTECTED]
        <mailto:[EMAIL PROTECTED]>.
        Can't post? Read http://www.gromacs.org/mailing_lists/users.php



-- David van der Spoel, Ph.D., Professor of Biology
    Molec. Biophys. group, Dept. of Cell & Molec. Biol., Uppsala University.
    Box 596, 75124 Uppsala, Sweden. Phone:  +46184714205. Fax: +4618511755.
[EMAIL PROTECTED] <mailto:[EMAIL PROTECTED]> [EMAIL PROTECTED] <mailto:[EMAIL PROTECTED]> http://folding.bmc.uu.se
    _______________________________________________
    gmx-users mailing list    [email protected]
    <mailto:[email protected]>
    http://www.gromacs.org/mailman/listinfo/gmx-users
    Please search the archive at http://www.gromacs.org/search before
    posting!
    Please don't post (un)subscribe requests to the list. Use the www
    interface or send it to [EMAIL PROTECTED]
    <mailto:[EMAIL PROTECTED]>.
    Can't post? Read http://www.gromacs.org/mailing_lists/users.php




--
Sapna Sarupria
Ph.D. Student - Chemical Engineering
Rensselaer Polytechnic Institute
Troy, New York 12180
U.S.A.
Ph#: (518)276-3031
Life isn't about finding yourself. Life is about creating yourself.
George Bernard Shaw.
Dare to Dream


------------------------------------------------------------------------

_______________________________________________
gmx-users mailing list    [email protected]
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php


--
David van der Spoel, Ph.D., Professor of Biology
Molec. Biophys. group, Dept. of Cell & Molec. Biol., Uppsala University.
Box 596, 75124 Uppsala, Sweden. Phone:  +46184714205. Fax: +4618511755.
[EMAIL PROTECTED]       [EMAIL PROTECTED]   http://folding.bmc.uu.se
_______________________________________________
gmx-users mailing list    [email protected]
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to