Manik Mayur wrote:
Hi Mark,

Thanks for your reply. I used tau_t=0 for the groups to which I do not wish to apply T-coupling as it was suggested in the manual. Could you please explain what did you meant by modifying tc_grps for removal of T-coupling for a certain group? As if I remove the specific group's name from the tc_grps, it gives an error saying that:
"X atoms are not part of any of the T-Coupling groups."
So what should I do now, I am really confused.

Hmm, I must be wrong on that point.

Now that I think about it, to decouple a thermostat requires a very *large* time constant tau, so if grompp requires T-coupling on all atoms or none, then the way to do what you want is to use a ridiculously large value of tau - say 10^20.

Mark