On Tue, 2009-06-02 at 11:13 +0100, Stefano Meliga wrote:
> The simulation seems just very slow.
> step 0 has appeared on the screen after several minutes and in the log 
> file there's only step zero as well.

You have 43 000 atoms and are using Ewald summation which is O(N^2), so
the simulation really is that slow.

Switch to using coulombtype = PME, that should speed things up.
-- 
------------------------------------------------------
Jussi Lehtola, FM, Tohtorikoulutettava
Fysiikan laitos, Helsingin Yliopisto
[email protected], p. 191 50632
------------------------------------------------------
Mr. Jussi Lehtola, M. Sc., Doctoral Student
Department of Physics, University of Helsinki, Finland
[email protected]
------------------------------------------------------


_______________________________________________
gmx-users mailing list    [email protected]
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to [email protected].
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to