Kirill Bessonov wrote:
Hello gain Justin,

Now I figured out that the problem was in gromacs version 4.0. So peptide in water works no problem.

I have used trjconv -pbc mol -ur compact and it solved the artifact problem. Thanks a lot!

Now I have started simulation on 96 CPU's for 1000ns total run time. But after 1 day simulation the system crashed or exploded with the following error: [First time it failed because of some problems with the server, and then I have resumed the run using tpbconv -s DMPCRun1000ns.tpr -f 1000nsDMPCA141Run_part1.trr -extend 100000 -o DMPCRun100nspart2.tpr]


Which simulation? Peptide in water, or peptide-DMPC? This will be important regarding the .mdp file you use.

Also, this use of tpbconv is obsolete. Use checkpoint files to obtain an exact restart.

vol 0.78 imb F 2% pme/F 2.15 step 10578400, will finish Sat Aug 29 07:23:01 2009 vol 0.77 imb F 3% pme/F 2.15 step 10578500, will finish Sat Aug 29 07:28:32 2009

Step 10578599, time 21157.2 (ps)  LINCS WARNING
relative constraint deviation after LINCS:
rms 0.299801, max 6.073617 (between atoms 9449 and 9450)
bonds that rotated more than 30 degrees:
 atom 1 atom 2  angle  previous, current, constraint length
   9451   9468   93.6    0.1530   0.1293      0.1530

Fatal error:
15 particles communicated to PME node 6 are more than a cell length out of the domain decomposition cell of their charge group

I am attaching my mdp files used to to EM and MDrun here:

EM: http://kbessonov.googlepages.com/em_lipid.mdp MD: http://kbessonov.googlepages.com/mdonly_1000ns.mdp

I was wondering why my system fails. and what can I do to avoid it? I was thinking maybe to run several times EM on the system, maybe it will help? What bugs me is that it fails really late in simulation. I have not seen trajectory file yet.


I'm guessing this is for your lipid system (based on the em.mdp file name)? What kind of equilibration are you using? Any position-restrained dynamics? If you're not, then you probably should be :)

Any other comments are subject to knowing what system you're really dealing with. If this is a peptide-membrane system, you'll need to make alterations to your handling of COM motion removal, temperature coupling, and pressure coupling.

-Justin



------------------------------------------------------------------------

_______________________________________________
gmx-users mailing list    [email protected]
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [email protected].
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

--
========================================

Justin A. Lemkul
Ph.D. Candidate
ICTAS Doctoral Scholar
Department of Biochemistry
Virginia Tech
Blacksburg, VA
jalemkul[at]vt.edu | (540) 231-9080
http://www.bevanlab.biochem.vt.edu/Pages/Personal/justin

========================================
_______________________________________________
gmx-users mailing list    [email protected]
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [email protected].
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to